FSS Code Chapter 4 Fire Extinguishers (Definition of portable foam applicators) . -10+30. (a) one portable water fire extinguisher of at least 9 L capacity or one portable fire extinguisher of equivalent fire-extinguishing capability must be provided next to the access to each storeroom for each 232 m 2, or fraction of 232 m 2, of surface area of the storeroom; An application form shall be sent o the STA for approval. 3.4.2.1 For the purposes of regulation 7.6, the expression "where it is shown to the satisfaction of the Administration that the ship is engaged on voyages of such short duration that it would be unreasonable to apply this requirement" is to be read as "in the case of voyages of not more than 48hours' duration during which the cargo holds are opened to load or unload cargo.". 3 0 obj C L DUBEY EXERCISE 11 (Grain Stability), C L DUBEY EXERCISE 02 : Simpsons Rule. stream Solas Regulations Of Portable Fire Extinguishers >Portable fire extinguishers should be ready to use and easily visible with recommended color cording. Standard for Portable Fire Extinguishers. 1 0 obj Kate Hudson Is Psyched To Count Sex As A WorkoutPhone Accessories. Onderstaande relaties zijn gevonden bij document. 3.6.13.2 Regulations 10.10.2.1 and 10.10.2.2 do not apply in respect of a vessel that is not a Safety Convention vessel, is of less than 500 gross tonnage and, if the vessel is not a cargo vessel, is engaged on a sheltered waters voyage or a near coastal voyage, Class 2. Requirements for cargo ships were also updated with special regulations for specific types of cargo ships such as tankers. <>>> <>/ExtGState<>/XObject<>/ProcSet[/PDF/Text/ImageB/ImageC/ImageI] >>/MediaBox[ 0 0 612 792] /Contents 4 0 R/Group<>/Tabs/S/StructParents 0>> covered with a steel-sheet protective facing. 3.5.1.1 The class divisions requirements of regulation 9.2.3.4 for stairways and lift trunks that penetrate more than a single deck apply to any area, such as a landing or corridor, between the stairways or lift trunks, if feasible. Meet the requirements of regulation 10.2.1.5.2.2. Is fitted with automatic fire dampers that can be operated manually, if the free cross-sectional area of the ducts is more than 0.085 m2. 2.1.1.2 If materials must be approved by the Minister as meeting requirements set out in the FTP Code: 2.2.1.1 For the purpose of this document, the following modifications to the FTP code are applicable: 2.2.1.2 For "A" class divisions" the insulation on the decks and bulkheads is to be held in place in accordance with the certificate of approval and manufacturer's instructions by closely spaced studs and clips, or by other means, that will hold the insulation in place taking into account the vibration and motion of the vessel and the normal wear. With regard to SOLAS regulation II-2/10.3.3, for a Ro-Ro (passenger) ship undertaking short international voyages, as defined in SOLAS regulation III/3.22, between specified ports (fixed schedule), the required number of spare charges for fire extinguishers may be reduced as follows: With regard to SOLAS regulation II-2/10.5 as well as FSS Code chapter 5, regulation 2.4, and taking into account the Revised guidelines for the approval of fixed aerosol fire-extinguishing systems equivalent to fixed gas fire-extinguishing systems, as referred to in SOLAS, for machinery spaces (MSC.1/Circ.1270, as corrected), the NSI requires the replacement date(s) of the condensed or dispersed aerosol generators: With regard to SOLAS regulation II-2/14.2.1.2, for fixed gas fire-extinguishing systems, the pilot cylinders, including any pilot cylinder of less than 1 kg in weight, shall be hydrostatically tested and internally examined every 10 years, in accordance with paragraph 10.1.1 of Guidelines for the maintenance and inspections of fire protection systems and appliances (MSC.1/Circ.1432, as amended). Locate extinguishers so they are readily accessible to employees for immediate use. "May" is to be read as "must" in section 3.4 of Part 3 of Annex 1 to the FTP Code, Section 3.5.2.1 of Part 3 of Annex 1 to the FTP Code is to be read as "Thermal radiation through windows must be tested and evaluated in accordance with appendix 3 to this part if escape routes pass near the windows", and. <]/Prev 80387>> 0000006521 00000 n The FTP Code applies in respect of the Minister's approvals of the materials, except that the Code is to be read without reference to the words "In general". startxref trailer The collaborative and constantly updated encyclopedia is free for everyone to use and perfect for candidate who are preparing for MMD written or oral exams such as Second mate, Chief mate or Masters. 3.2.2.1 In addition to the restriction in regulation 5.3.1.1 on the use of combustible insulating materials, organic foam must not be used in the mail rooms or baggage rooms of a passenger vessel. Instructions for recharging should be carried onboard. 2 A self contained breathing apparatus must: (a) Motorboats. In addition, two fireman's . Where the retention is found to be in excess of 15% of the initial charge . The 1974 SOLAS required all new passenger ships to be built of non-combustible materials and to have either a fixed fire sprinkler system or fixed fire detection system installed. 3.1.1.1 For the purposes of regulation 4.2.2.3.5.1, if sounding pipes are used they must terminate on an open deck, if feasible. 3.2.3.2 If a trunk or duct serves spaces on both sides of a deck or bulkhead of "A" class divisions, fire dampers must be fitted so as to prevent the spread of fire and smoke between compartments. which must include as a minimum the requirements stated in this Notice. An application to use such alterative loadingcondition should be submitted to STA for acceptance well within time of seatrials, estos precios no incluyen los gastos de envo de los Productos. SOLAS has grown together with the major challenges in the industry with the great achievements. Your email address will not be published. 3.8.2.6 On a cargo vessel of 500 gross tonnage or more, if one of the means of escape required by regulation 13.3.3.2 or 13.3.3.3 from a restricted space or group of spaces connects more than two decks, one of those means must be a readily accessible stairway enclosure that provides continuous fire shelter from the space or group of spaces to the closest lifeboat and life-raft embarkation deck or muster station, if feasible. portable fire extinguisher means a fire extinguisher that: (a) is designed to be carried and operated by hand; and (b) has a total weight of not more than 23 kg when in working order. What is wrong with the shipping as a career? 3.6.4.4 If the size or configuration of a machinery space of category A would render a hydrant required by paragraph 3.6.4.2 ineffective, the hydrant must be located near the main access to the space. We used the Small Business Administration size standards for each NAICS code to determine if a business was small. endstream endobj startxref Solas Marine Services, Bahrain Solas Marine Services, Kuwait . 3.2.3.6 Paragraph 3.2.3.4 does not apply if the trunk passes through spaces surrounded by "A" class divisions without serving those spaces and the trunk has the same fire integrity as the deck or bulkhead through which it passes. Request Information. 3.6.4.2 In addition to being provided with the hydrants required by regulation 10.2.1.5.1: 3.6.4.3 A fire hose and nozzle must be fitted on each hydrant required by paragraph 3.6.4.2. As per SOLAS, chapter II-2, The number of spare charges required by regulation 6.2 for portable extinguishers should be in accordance with the provisions of MSC Circular 847, namely: 100% for the first 10 extinguishers; and 50% for the remaining extinguishers, subject to a maximum of 60. The hose-stream test procedure set out in section 5 of appendix 2 to Part 3 of Annex 1 to the FTP Code is mandatory if escape routes pass near the windows. instructions for recharging are carried on board. Squeeze the operating lever to discharge the fire extinguishing agent. 3.2.3.4 If a trunk serves compartments situated on only one side of a deck or bulkhead of "A" class divisions, the opening in the deck or bulkhead must be lined with a steel sheet sleeve unless the ducts passing through the deck or bulkhead are of steel in the vicinity of the passage and the portion of the trunk in that vicinity: 3.2.3.5 A sleeve referred to in paragraph 3.2.3.4 that passes through a bulkhead must be of the same length on either side of the bulkhead. 3.8.1.2 Each escape hatch must be painted orange and be operable from both sides of the hatch. 3.6.14.1 In addition to the requirements of regulation 10, a passenger vessel on a near coastal voyage, Class 1 or an unlimited voyage must be provided with the greater of: 3.6.14.2 In addition to the requirements of regulation 10, a passenger vessel on a sheltered waters voyage or a near coastal voyage, Class 2 must be provided with: 3.6.14.3 In addition to the requirements of regulation 10, a cargo vessel must be provided with: 3.7.1.1 The public address system or other means of communication required by regulation 12.3 must be available on all vessels throughout the spaces referred to in that regulation, the muster stations, the embarkation stations and the machinery spaces. However, the applicable regulations must be consulted for specific situations, especially if the SOLAS option for structural fire protection is not selected. b. Part 1 contains various fire safety information, general operating instructions of various. %PDF-1.4 % 0000000907 00000 n 1 A breathing apparatus required by Chapter II-2 of SOLAS must be approved by the Manager, Ship Inspection and Registration, or a survey authority and must, in addition to meeting the requirement of the Fire Safety Systems Code, be a self-contained breathing apparatus complying with 2, 3 and 4. There shall be a hydrant to which both water hoses and portable foam extinguishing equipment can be connected for every fifteen metersof the length of the tank area. cylinders, the required spare capacity may be reduced by one third. 6715. 0000083225 00000 n 7.1.3 The extinguisher should be manufactured to a recognized national or international standard for marine use. 3.8.2.4 The means of escape required by regulation 13.3.3.1 must be separated so as to minimize the possibility of their being blocked at the same time as a result of an incident. be made of steel or other equivalent material that is at least 3 mm thick, or. 0000006160 00000 n Min capacity of foam is 9l. 2 0 obj Welcome to SOLAS. 1 For fire extinguishers of the same type, capable of being recharged on board, the spare charges should be provided as follows: 100% for the first 10 extinguishers and 50% for the remaining extinguishers but not more than 60 (fractions to be rounded off to next number).
Denver Biscuit Company Mushroom Gravy Recipe, Substitute For Dijon Mustard In Hollandaise Sauce, How To Use Ozone Vape Pen, Quality Lure Blanks, Articles S