Is there something on the board I need to change? Cheers! This quick spray of water when you shut the pump off, as you have experienced, are a useful tool in locating an air leak on a pump. None of the indicating lights are on. There should be NO elbow after the flow switch. Spray some ant killer around, and replace the capacitor, but first, check all connections, maybe check incoming power (to the motor) if you have a test meter. The pump does not start. Is there something special I need to do when first installing the motor? IE9 and older versions are not supported. Hi Jodi, perhaps the rod is not threaded all the way into the base, or there may be debris under the rod, preventing it from going down fully. If it does not, keep reading. Plate appeared to be good. Full membership to the IDM is for researchers who are fully committed to conducting their research in the IDM, preferably accommodated in the IDM complex, for 5 We would like to show you a description here but the site wont allow us. Since that time the mechanical seal has failed four times each time within 2 months of operation. Setting it up this year and the pool filter lid keeps leaking. This time around I purchased the t-3 cell model since my pool is below 15k gallons. Tried to backwash. And 93, thats just the temp of the water, the flames are much hotter of course, thats what is melting the plastic. Is it problem of filter ? The heat sink is a ridged metal plate beneath the drive, that relies on air flow to help remove heat from the motor. What can I do? It could be a problem the other way around, AG pumps cannot lift water vertically, so are not used on inground pools. Hi, that could be many things, from low water level to a broken impeller, but its usually an air leak. Any ideas on how to fix this issue?? $8.99 $5.99 As low as $4.49 Dow Corning - Molykote 111 6 gram O-ring Silicone Lubricant and Sealant - Be sure to lube your O-rings to help prevent leaks. They disparate as they move through the pool. If you attached the cord, make sure that the wires are correctly attached to the terminal board, and the ground wire secure. Hello. I disconnected it and plugged the Aquatrol in alone; that worked fine. Running at low rpm seems to be fine. 5. Thanks for your time! filter. Not that the motor shuts off So, to backwash, you are shutting off the pump, turning the multiport valve to backwash, turning the pump on, but water does not flow out of the waste line? I would like to repair it if possible. Hey John I even tried running the new line downhill and then back up some to hold water in the piping. On a Hayward pump with clogged impeller, you can remove the basket, reach through the small hole with your fingers (pump off! For a better experience, please enable JavaScript in your browser before proceeding. Help! Im having a problem with my super pump. Hi Mike, when there is no wiring diagram printed on the motor label or above the nameplate, indicating High/Low Voltage wiring specs, then the motor is not reversible. I replaced the pump thinking it was bad. Is the water level ok in the pool, and the skimmer weir is not stuck? When it stops again, you may want to pull off the filter valve from the filter, and inspect the top few inches of sand, maybe replacing it with new. We have an Hayward SP1580X15 Power-Flo LX 1.5hp pump. Is this the problem and should I get i checked or just replace it? I am thinking it must be the age of the pump. Have no power at all going to my control panel. Most heaters can operate on 120V/240V, either one. It had a non Hayward motor installed before. Please ignore my previous question I put a slight bend in the end of the wrench and was able to get a grip on the shaft , When I opened my pool the pump hummed and did not start. After running almost 24 hours the pressure went upto 30 which is the maxium number on our filter gauge and the water circulation stopped. The motor has all of the same specifications of the Hayward motor that is being replaced, what could possibly cause the motor not ot work? I had an old hayward 1.5 hp power flo matrix 2 speed pump. On traditional intermatic time clocks, you also have to make sure the timer dogs are tight, or they can slip, use pliers to tighten the nut tighter to avoid. If the amps on either reading show zero (0), then you should replace your PC Board. $579 + Free Shipping in USA. it continues to cycle this way. Any idea what the problem could be? Mine is doing same thing. If the No Flow LED is flashing, wait 60 seconds after starting your pump and filter. Automation, Learn About Breaker for the pump is not tripped. It appears to be stuck. The mechanical shaft seal sits behind the impeller, and prevent water from leaking out along the motor shaft. I know I have power going to the unit, as I can hear it go on and off in the transformer, when I hit the switch. Still the same results. The arrow should point in the same direction as the water flow. Hi Shelly, sounds like maybe the board got wet, or there is a loose connection, or power supply issues. The cap is located at 9 oclock in the rear of the motor, when they go bad, they sometimes bulge or crack, or turn brown or smell strongly of burnt wires They are cheap to replace, worth a shot, replace with identical MFD number. Just be sure to buy the correct seal for your make/model pump, for the Powerflo Matrix pump, thats here: https://www.intheswim.com/p/hayward-spring-seal-w-seat-spx1250xz2c SPX1250XZ2C. Something about level of placement of pump in relation to the water surface. Same with other sensors. The motor may be dead, or possibly not. If pressure is lower than normal check for air leak on the suction side of the pump, or a clogged impeller, or low water level, stuck skimmer weir, or closed suction valves. After communication is established, if it is lost for 30 s, the error will be displayed. Not the power leads, but other connecting wires from the terminal board to the switch, to the cap? Dear Davy, my pump was working two days ago then I switched it off. You must log in or register to reply here. I just replaced my pool pump motor because it was really loud and i figured it was the bearings. Hello. Hi Jim, as I like to say, the problem lies, where the power dies. Christin, many aboveground pumps plug into a GFCI outlet, check that the TEST button is not popped out. I live in Tampa Florida. If the shaft spins freely, no rust problem. Sometimes I need to backwash and rinse before the water seems to get going enough to actually circulate, then Im able to switch to filter and it works. Hi Theresa, if the pump is overheating, and shutting off for 20 minutes to cool down and then starting again, thats not usually a good sign, altho could be incorrect voltage or loose connections. Check if the pump will now run. Zeolite Market Share In 2022 | Top Players [ Shanghai Hengye, Zeotech Corp, Blue Pacific Minerals (BPM), UOP (Honeywell) ] In-Depth Analysis, Forecast to 2027 with Top Countries Data | The Twelfth Edition of Business Research Methods reflects a thoughtful revision of a market standard. Why does this keep happening? Hi Ray, the GFI breaker you replaced, is that the pump breaker? SOme pumps have an open bracket where you can see the shaft, but not Hayward. outlet still on. When you first turn it on it works great with strong suction. Question, if I can determine which return pipe is broke could I just block off that return and bypass it. I then plugged the pump into the outlet and it tripped again. Ohms reading should be between 0.5 and 1.0 ohms max. I even tried another new housing gasket and it still leaks. It has now been two days since the technician was here and the pump is still pushing de into the pool at lower RPM speed. Hi Nancy, Heat Sinks are designed to absorb the heat from the motor, and dissipate it safely. Lighting Equipment Hayward Sense and Dispense AQL-CHEM Troubleshooting Manual (36 pages) Lighting Equipment Hayward SwimPure Plus Operation And Installation Manual (20 pages) Lighting Equipment Hayward Sheer 500 Owner's Manual Water feature with led lighting (16 pages) Lighting Equipment Hayward OmniHub Installation Manual We have a Hayward 1.5 lx. If not the skimmer being blocked, then its an air leak BEFORE the pump impeller. presto, all working good! When we turn on power, the pump does not make noise but the timer box and the circuit box make a light humming noise and then the circuit tripped. Do they sometimes have to be replaced? If you can remove the handle, you can apply shaving cream and run the pump to see if it gets sucked in put cream around the stem and on both joints in/out of the valve. Have a Hayward 1HP self priming super pump on an older pool the motor bearings are screaming. Put everything back in place, turned pool on. If not, you should cut out the fitting and replace, smearing on some Blue RTV sealant, and then wrapping the threads completely in 3-4 layers of Teflon tape before screwing it into the pump. I remplace it and now the sistem works!! If the motor hums, buzzes, or tries to start, but trips the breaker (or not), could be a bound-up shaft, super clogged impeller, bad capacitor, or bad motor. But not a dirty filter? We just verified all our time settings. Anyone else have a scientific explanation? I have a Hayward North Star that I rebuilt with new motor, shaft seal, all new rubber seals, impeller, and diffuser. If the problem continues after fixing the problems above, you may have a clog in the suction side of your pump. It is plugged into a gfi outlet. Hi Damon, I would suspect the chattering sound to be a loose stationary switch and/or centrifugal switch on the motor, in the rear of the motor, remove the cover and look for something amiss. Then, take a look at the capacitor, located at 9 oclock. Motors that are reversible always ship from the factory at 230V, and need to be manually switched to accept 115V. We purchased a Hayward D.E Filter last summer. Click here to shop our store. I opened my pool this weekend and started the pump and let it run for few hours before stopping it. Thanks for the comment! Probably a loose fitting, clamp or o-ring. We believe it needs a new seal. Usually however, a howling or moaning sound from the pool heater, is low water flow. Free, Pool Equipment Parts: Make your Own Repairs, https://www.intheswim.com/p/hayward-super-pump-pool-pump-motor-1-5-hp-threaded-shaft, https://www.intheswim.com/p/hayward-super-pump-shaft-seal-assembly-spx1600z2, http://waterheatertimer.org/How-to-wire-Hayward-two-speed-pump.html, https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/super-pump-vs-S2603VSP.pdf?fromCDN=true, https://www.intheswim.com/c/filter-parts?pcode=208&scode=SOCIBLOG, https://www.totallyhayward.com/techservices/attachments/Serial%20Number%20Read%20REVISED%201-2012.pdf, https://www.intheswim.com/images/PDFs/E1964-Manual.pdf, https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/tristar-vs-S3202VSP.pdf?fromCDN=true, https://www.intheswim.com/c/pump-parts?pcode=208&scode=SOCIBLOG, https://www.intheswim.com/p/hayward-spring-seal-w-seat-spx1250xz2c. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Loose connection inside the plug or socket. replacement. Write Review Hayward AquaTrol HP Main PCB | GLX-PCB-TROL-HP $375.97 Quantity $17.35 / Month * Platinum Preferred Manufacturer Proposition 65 Warning Automatic reset is immediate once the gas valve relay check results are acceptable. Could be clogged impeller? I have a pre-2008 Northstar pump and it seems to be losing air seal. Profile, Create a Pool Professional LibriVox is a hope, an experiment, and a question: can the net harness a bunch of volunteers to help bring books in the ' '' ''' - -- --- ---- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- Occasionally the salt level on the Hayward Aqua Rite may not match the actual salt level of the pool. ' I also made sure that the board was changed from T9 to T3 cell. Hi, I have a Hayward pump and it was running my barracuda g3 just fine but it stopped hours later. What do you think? Loose pump lid, filter lid, air bleeder, probably around the filter, allowing the filter to drain down, and fill with air. For plug-in pumps, be sure the TEST button is not tripped on GFCI outlets, and that the cord is not damaged. If your cell looks like 4A, continue to Step 4. Clean Gasket (no bits of debris or de powder), 2. When I turn the switch on for the pool, the breaker flips immediately. My wear ring fits very loosely and it seems like impeller shaft has worn down. My pump was tripping the breaker after about three minutes (consistently when I reset the breaker and turned on the pump, same thing). I replaced my old hayward maxflow pump with the new variable speed sp2670020vsp. i just installed a vspnp hayward pump and when i flip the breaker on it only makes a clicking noise. I would also check all the wire connections (power off) to be sure they are tight, on the breaker and on the time clock, and also inspect for insect infestation, or lizards, mice, etc. Hi Cortney, you can buy the cord separately, Hayward pump cord the cause is likely from something arcing within the plug outlet. I needed to rotate the housing pump but for some reason the screws dont seem to b lined up. When iturned it back on, it ran for a few seconds, sounded funny, then shut off. Capacitor is a battery in the back of the motor, at 9 oclock that assists in starting the motor, if the capacitor was weak, that may draw more amps from the breaker. While distracted pouring the Blue Nun, This Week missed the irony that in the decade Japan opened its first Shinkansen Bullet train route Britain was running down and closing main lines. The rooms are equipped with a [] | Egypt Travel & Tourism Agency. If all is well then 99% sure it would be the capacitor, weak and needs replacement. Air can also enter the system from low water level or a stuck skimmer weir, bringing air in from the skimmer, or from loose and leaky suction side (skimmer/main drain) valves. Recently I started getting a loud vibration hum from my hayward pump. All Products, View No pressure now. Did you figure this out. Could be the pump lid, drain plug, or the pipe that threads into the pump. Third, could be a clog in the main drain or skimmer (suction) pipes. Something got fried, sorry! Hi, yes shaft seal failure. In the meantime, could you send me a link for the capacitor that I need? thanks. Attached please find a copy of the Aqua Plus Operation Manual Please note Section - Configuration Menu Items, Cell Type Selection, page 16. It appeared that I couldve pulled them right off if I tried. Also look for any burn marks on the wire terminal board, or any crimped wires running round the rear of the motor. Note: Antimicrobial properties are built in to the blue filter media to inhibit the growth of bacteria that may affect this product. Im assuming that the motor makes no noise at all? If the new pump produces greater flow rate than the old pump, it produces high pressure, and poor filtration, and can damage the cartridge. Thanks! If it does make a humming or buzzing sound briefly and trips the breaker, check that the shaft rotates the impeller freely, and if so, replacing the capacitor is usually the fix. Where can I get a new yellow wire to connect the motor to the switch and see if this solves my issue? could be cord problem, too. The AquaTrol Are T-Cells interchangeable on Hayward AquaRite Systems? You can remove the wires and call your local Electric Motor Repair Shop, and see if they have this capacitor in stock, just read them the MFD number range printed on the side of the black cylinder. Motors have a thermal overload switch which will shut off the motor if it gets too hot to operate, and in such cases, it will turn itself back on again after it cools, usually in 15-20 mins. Would this make the breaker flip? I have a new pump and brand new grid inside my filter i have no leaks after about 10 minutes my jets stop i back wash filter and it works for about 10 min again i am stumped. It ran and then we shut it off. It can also be a loose pump lid allowing air to creep in around the o-ring. Well the electrician said it was a bad motor and to contact hayward to replace. Home / Pool Equipment / Pool Pumps / Hayward Pool Pump Troubleshooting. One of them was arguably the best-constructed route from London [Marylebone] to Manchester. We just has this pool installed year, and brought the motor inside the house. Ob, and its just over 4 yrs old. Thought it was air leak, finally decided to check filters (pressure was 35 lbs after cleaning). So, when a pump is surging or pulsing, and not getting up to full head it is either starved for water, because of closed incoming valves, or too big of a pump for too small inlet pipes or because of air being pulled into the pump from air leaks or low water level in pool or from some obstruction in the lines, pipes or valves, a clog or something broken off I have found a Drain King useful in diagnosing such things, find at a hardware store, the 1.5-2 model, and connect to a garden hose, to pressurize pool systems and pipes, to look for leaks, or used as a water hammer to force clogs out, back the other way. Hi Lo in checking the owners manual https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/tristar-vs-S3202VSP.pdf?fromCDN=true, it suggests bypassing the timeclock and wiring direct to the breaker. Wouldnt, the other three still be sufficient to filter? So my Hayward melted the whole left sided plastic shrouds. If you have a filter pressure gauge, the practice is to clean the filter when the pressure gauge rises 7-9 psi above the clean, starting pressure. Then dunk them in the pool quickly after the acid, to rinse cleanly. I have my pump to run each evening from 10:30pm to 9:30am. Anyway I decided to run it and it appears that the pump runs full power with the returns pushing out with lots of force for about 5 minutes and then it weakens. Do you have any idea what I need to do to remedy the problem. I would recommend getting a plug-in timeclock so you dont need to plug/unplug it all the time. The pump should really be on its own breaker if possible. Check that the pump lid is on very tight, and that the threaded fitting that screws into the front of the pump has Teflon tape or other thread sealant. Are you using DE powder or enough DE powder? For slide valves (aka push-pull valves), an o-ring on the bottom plunger disk has gone missing or is worn, torn or badly deteriorated. Samsung Da29-00020b 3 Pack, Cleaners Controls Filters General Pool/Spa Heat Pumps Heaters Lighting Pumps Robotic Cleaners Sanitization Step 3: Select model to register. Step 2: Did you properly install your switch? We have a Hayward ultra pro lx series pump for our above ground pool. We are out of ideas and no one can solve this. No matter where we move dial we have water coming out the back wash pipe. I think it only screws on in one direction, but unscrew it to check When in Filter Position, water should route in only one direction. If your motor is overheating, and shutting off (from the thermal overload switch, located in the back, at 12 oclock), then you have some motor issues, maybe blocked air vents, broken internal fan, or a short across the windings. Thanks. 1.5 hayward pool pump motor clicks on and off rapidy. Check all wires and switches and connections in the back of the motor, look for anything loose or ant infested or broken connections. Ive tried setting up the vacuum with power on and power off and its no different. Hi Finally, it could be bad voltage, but again, it was running before just fine, so probably not that. hopefully. Thanks. 1. You will get much more visibility by. Hi, We had a pool installed last fall and we are still figuring things out. Any part # you can recommend ? If one of the keypad buttons is closed (or pressed) for more than 30 s the error code will be displayed but the control will continue to function. If that all checks out, be sure that there are no air leaks on the suction side of the impeller, around the lid, drain plugs or pipe coming into pump. Check power at the switch or timer in the same way as the motor, at the other end of the wires running between the switch/timer and motor. I am getting air bubbles coming from my return jets in my pool. Hi, I have a Hayword pump and when I turn the pump on I have water coming out the bottom of the pump in the back, and trips the GFI OUTLET, could this be a bad seal? The repair for such an issue is to remove the 6 screws around the lid (dont lose the nuts), and pull the handle to lift the key assembly out of the valve body, where you can inspect the gasket, in the area of the backwash port. Ohms reading should be between 0.5 and 1.0 ohms max. Is it rigid PVC or flexible pipe? I have a humming noise when plugged in, but can seem to get the cover off. After running the pool for a few hours we realized the pump was leaking and EXTREMELY HOT. Another possibility could be a clogged pump impeller, should have mentioned that earlier. Hi Sam, I suppose a dead battery (capacitor), but there would be some noise or hum, as the motor tried to start, then would trip the breaker. I heard like a crank sound, as if somethings stuck between a propeller if there is. Third time turned off pump same thing happened with humming and eventually kicking in. If you have a multiport valve you could put it on Recirculate to bypass the filter, but Avalanche filters dont have one do they? The early revisions dont work with the TCELL5 or TCELL9. Perhaps you can replace it with a 20 amp breaker, of the same manufacturer, and youd be all set, or move some of the other devices to draw power from a different breaker. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
Hello we have a Hyward Power Flo Matrix 1 HP pump for a 15 foot above ground pool the pump runs however only seems to fill the strainer basket half way and is very noisy (like its struggling to get enough water in) the pressure guage on sand filter reads 15 psi and everything has been cleaned and new o-rings installed all around. Is there a disconnected wire in the back of the motor? Thanks. Heaters, Learn About If you have power coming into the motor, but no pump noise, check (Power off) that wire connections are tight, and inspect the wire for breaks or damage. Tough one, good luck! But not likely, since its been there for years. 2. ), to see if air is drawing in around the fitting. Replace with the exact same MFD number capacitor if defective (they can be tested) the capacitor is the battery that starts the motor. Can you help? my two speed Hayword pump clicks when what do you think the hum could be? I primed the pump and was ready to add DE compund. The idea is to cut the pipe above the pump, and crank the fitting 1/2 turn tighter, to open the crack, pump it full of superglue and then quickly unthread the pipe out of the pump, at which point the crack will close up, and hopefully seal up. Flip timeclock switch on, inspect time clock motor gears (Intermatic clocks) for good timer motor, and inspect wiring from timer to pump. Flip the switch opposite, and you should be all set. If you have an automatic controller, it could be a rickety relay or something. The pump is working fine, however only the low speed is working. The hotel has an excellent location, close to a wonderful coral reef, lagoon with natural pool and sandy beach, outdoor swimming pool available all year round, private beach area, kitesurfing center and bar. Mark. After installing the new pump, priming it, it started running as normal, after a short time the new pump shut down and was very hot. Has worked fine until today. Thank you. 1. Maybe not a pump issue, but supply issue. I am getting 24VAC from top Rectifier to PCB Input, says it should be 12VAC. From the Hayward Ecostar Owners Manual: the Heat Sink Overheated error indicates that the heatsink on the bottom of the drive has overheated. I just replaced the seal and all of the gaskets along with carefully cleaning the grooves that the gaskets rest in and greasing them thoroughly with Jacks. Maybe thats off. Now when my sweeper comes on my waterfall feature from my spa does not turn off like it should and my sweeper moves slowly and in circles. The Aqua Rite is protected by a 20 amp mini ATO fuse located on the circuit board above the cell connector. What seems to be the problem. Blower vacuum switch closed when expected open error, If the blower prover switch is closed before blower start-up the control will not start the blower. Hi, if the spark/flame was where the plug meets the cord, it could be a plug problem or an outlet problem. Even though the motor is only 2 months old and had very little run time, bench running it sounds pretty horrible. When I flip a switch to manually turn on to high speed, it does not work it is still working at low speed. But the process seems to take way too long. It just started leaking at the top plumbing connection. Any tips on getting the cover off to get to the capacitor (after removing the two screws)? Any thoughts? ring wont spin loosely around but it didnt seem to help. Just replaced the sand and cleaned the fingers, replaced the o rings and have a psi of 15 and great suction. Click OK to extend your time for an additional 0 minutes. Are I on the right track? Loose wiring, or broken wires, or wires nearly touching each other, and arcing.